TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
21
2000 Hours
1.0 Hours Hydraulic
d. Remove, clean, inspect, and rein-
(Con't) or Annual
System
e. Replace hydraulic system oil filters
f. Remove retaining ring and clean
strainer at fill opening. Reinstall
strainer.
g. Inspect fill cap gasket and replace if
damaged.
h. Fill tank with oil (Item 24 or 29,
sight gage. Install fill cap.
i. Start engine and bring hydraulic
system to operating temperature.
Oil level must be above bottom line
on sight gage. Add oil as required.
OIL MUST
BE ABOVE
THIS LINE
0010 00-66