TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
NOTE
19
2000 Hours
1.0 Hours Front Axle
or Annual
Differential
Front axle final drive capacity is 1.5 gal. (6 L).
and Final
Front axle differential capacity is 5 gal. (19 L).
Drives
Clean area around fill and drain plugs prior to removing.
a. Park machine on level ground with
plugs at wheel end final drives ori-
ented at 6 o'clock. Remove plug,
O-ring, and seal at each wheel end
and drain oil into a suitable con-
tainer. Dispose of oil in accordance
with local policy and ordinances.
Discard plug O-ring and seal.
b. Remove level/fill plug from differ-
ential. Remove drain plug and seal
and drain oil. Discard seals. Clean
drain plug and reinstall with a new
seal.
LEVEL/FILL
PLUG AND
SEAL
DRAIN PLUG
AND SEAL
DIFFERENTIAL
0010 00-63