TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
15
Semiannual
Wheels and
a. Inspect tires for general condition
Tires
and proper inflation of 45 psi (310
kPa). Replace any missing valve
stem caps.
b. Inspect tires for wear. If tread depth
is 10 mm (0.39 in.) or less, or if
operator has reported a critical loss
00 or TM
5-3800-205-23-2).
c. Check for loose or missing lug nuts.
Correct lug nut torque is 370 lb-ft
(500 Nm).
d. Inspect brake discs for excessive
scoring and pitting. Replace if
excessively scored or pitted (WP
0080 00 or TM 5-3800-205-23-2).
Check level of oil in bearing housing
16
Semiannual
0.3 Hours Water Pump
of water pump:
Bearing
Housing
a. Access water pump under steps at
rear of water distributor.
b. Clean area around level and filler
plugs with a clean rag (Item 31, WP
c. Remove level plug. Oil should be
level with plug.
d. If level is low, remove filler plug
and add oil (Item 24 or 29, WP
from level plug. Clean level and
filler plugs and install.
0010 00-56