TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
Open engine access door and access
10
Semiannual
Engine
on left side of engine compartment.
Breather
Clean breather:
Assembly
a. Loosen clamp and remove hose
from cover of breather.
b. Remove bolt, washer, cover, and
breather element.
c. Inspect cover seal for damage.
Replace seal if damaged.
WARNING
Solvent cleaning compound, MIL-PRF-680 Type III is an envi-
ronmentally compliant and low toxic material. However, it may
be irritating to the eyes and skin. Use protective gloves and
goggles. Use in well-ventilated areas. Keep away from open
flames and other sources of ignition. Failure to do so may result
in injury or death to personnel.
Compressed air used for cleaning or drying purposes, or for
clearing restrictions, should never exceed 30 psi (207 kPa). Use
protective equipment and exercise caution to avoid injury to
personnel.
0010 00-51