TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
NOT FULLY MISSION
CHECK/
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
SERVICE
8
500 Hours
or Semi-
annual
WARNING
DO NOT perform fuel system checks, inspections or mainte-
nance while smoking or near fire, flames or sparks. Fuel may
ignite, causing damage to machine and injury or death to per-
sonnel.
Operating personnel must wear fuel-resistant gloves when han-
dling fuels. If exposed to fuel, promptly wash exposed skin and
change fuel-soaked clothing.
a. Replace fuel system primary and
secondary filters (TM 5-3800-205-
ual).
b. Disassemble and clean fuel tank
cap:
(1) Remove fuel tank cap.
(2) Remove gasket from cap and
inspect for damage. Replace
gasket if damaged.
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an
environmentally compliant and low toxic material. However,
it may be irritating to the eyes and skin. Use protective
gloves and goggles. Use in well-ventilated areas. Keep away
from open flames and other sources of ignition. Failure to do
so may result in injury or death to personnel.
(3) Disassemble fuel tank cap:
Remove
valve
assembly,
washer, baffle, gasket, and filter
elements.
0010 00-49