TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
NOT FULLY MISSION
CHECK/
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
SERVICE
(4) Clean elements in solvent
8
500 Hours
cleaning compound (Item 6,
(Con't) or Semi-
annual
for damage and replace as
needed.
(5) Apply a thin coat of oil (Item
ments and assemble cap.
Tighten valve assembly to 177
lb-in. (20 Nm). Install fuel cap
gasket.
GASKET
VALVE ASSEMBLY
VALVE
ASSEMBLY
FILTER
FILTER
WASHER
BAFFLE
ELEMENTS
ELEMENTS
f. Remove strainer from filler neck of
fuel tank. Clean strainer in dry
g. Install strainer into filler neck.
Install fuel tank cap and tighten
securely.
1.0 Hours Hydraulic
a. Replace hydraulic system oil filter
9
500 Hours
System
or Semi-
change hydraulic system oil at this
annual
time (Refer to Annual interval).
b. Clean hydraulic tank relief valve
0010 00-50