TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
NOT FULLY MISSION
CHECK/
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
SERVICE
d. Wash breather element in solvent
10
Semiannual
Engine
cleaning compound (Item 6, WP
(Con't)
Breather
compressed air.
Assembly
e. Inspect hose and replace if dam-
aged.
f. Install breather element and cover
with washer and bolt. Tighten bolt
to 62 lb-in (7 Nm).
g. Install hose to cover and tighten
clamp.
BOLT AND WASHER
CLAMP
COVER
HOSE
0010 00-52