TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
NOTE
17
1000 Hours
1.0 Hours Transmis-
or Annual
sion
Machine should be parked on level ground, with transmission
in Neutral (N) and locked with parking brake applied. Shut
down engine.
Transmission fluid will drain easier if warm.
Transmission fluid capacity is 9.2 gal. (35 L).
Clean area around fill cap and drain plug prior to removing.
a. Remove cap from transmission fill.
CAUTION
Install drain tool finger tight only until oil starts to drain. If
drain tool is forced into valve, damage to valve and leakage
will result.
0010 00-59