TM 5-3800-205-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0010 00
Table 8. Unit Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
17
1000 Hours
1.0 Hours Transmis-
b. Remove drain plug and O-ring
(Con't) or Annual
sion
from transfer case. Insert drain tool
into drain valve and turn tool finger
tight to drain transmission fluid into
a suitable container. Dispose of
fluid in accordance with local pol-
icy and ordinances. Discard O-ring.
Clean drain plug and reinstall,
using a new O-ring.
TRANSMISSION
BREATHER
FILL
DRAIN PLUG
TRANSFER
390-010
AND O-RING
CASE
DIPSTICK
c. Replace transmission oil filter (WP
d. Remove, clean, and reinstall trans-
mission oil suction screen and tube
assembly (magnetic screen) (WP
e. Remove, clean, dry, and reinstall
transmission breather.
0010 00-60