TM 5-3800-205-23-1
ETHER COLD START AID SYSTEM MAINTENANCE - CONTINUED
0022 00
ETHER CYLINDER REPLACEMENT
1.
Loosen thumbscrew (3) of retaining clamp (2) and
1
rotate ether cylinder (1) counterclockwise to remove
from solenoid valve (4).
2.
Remove gasket (5) from solenoid valve (4). Discard
2
gasket.
3.
Position new gasket (5) in solenoid valve (4).
4.
Install ether cylinder (1) on solenoid valve (4) by
rotating clockwise until hand tight.
3
5.
Tighten thumbscrew (3) of retaining clamp (2).
4,5
CLAMP AND SOLENOID VALVE REMOVAL
1.
Remove ether cylinder (refer to Ether Cylinder
2
Replacement).
6,7,8
2.
Install protective cap (10) on solenoid valve (4).
3.
Remove two nuts (6), screws (7), four washers (8),
9
and retaining clamp (2) from left fender bracket (9).
4.
Remove solenoid valve connector (14) and wiring har-
ness (19) from clip (15). Disconnect connectors.
10
5.
Remove fitting (12) and tube (13) from elbow (11).
19
6.
Remove elbow (11) from solenoid valve (4).
4
7.
Remove two nuts (16), screws (17), four washers (18),
11
16,17,18
clip (15), and solenoid valve (4) from left fender
15
12
bracket (9).
14
13
0022 00-2