TM 5-3800-205-23-1
ETHER COLD START AID SYSTEM MAINTENANCE
THIS WORK PACKAGE COVERS
Ether Cylinder Replacement
Clamp and Solenoid Valve: Removal, Installation
Ether Atomizer Replacement
INITIAL SETUP
Equipment Condition - Continued
Maintenance Level
Unit
Scraper bowl or water tank lowered to ground
Tools and Special Tools
(TM 5-3800-205-10-1 or TM 5-3800-205-10-
2)
Tool kit, general mechanic's (Item 33, WP 0172
Parking brake applied (TM 5-3800-205-10-1 or TM
Materials/Parts
5-3800-205-10-2)
Gasket
Wheels chocked (TM 5-3800-205-10-1 or TM 5-
O-ring
3800-205-10-2)
Equipment Condition
Battery disconnect switch in OFF position (TM
Machine parked on hard, level surface (TM 5-3800-
5-3800-205-10-1 or TM 5-3800-205-10-2)
205-10-1 or TM 5-3800-205-10-2)
WARNING
Ether fuel is extremely flammable and toxic. DO NOT smoke and make sure you are in a well-ventilated
area away from heat, open flames or sparks. Wear eye protection. Avoid contact with skin and eyes and
avoid breathing ether fumes. If fluid enters or fumes irritate the eyes, wash immediately with large quantities
of clean water for 15 minutes. Seek medical attention immediately if ether is inhaled or causes eye irritation.
Failure to follow this warning may cause death or serious injury to personnel.