TM 5-3800-205-23-1
STOP LAMP PRESSURE SWITCH REPLACEMENT - CONTINUED
0058 00
INSTALLATION
1.
Apply antiseizing tape to threads of pressure switch (2) and install pressure switch on control valve (1).
2.
Connect electrical leads (3) to harness connector (4).
1
2
4
3
END OF WORK PACKAGE