TM 5-3800-205-23-1
AIR TANKS REPLACEMENT - CONTINUED
0094 00
INSTALLATION - CONTINUED
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Ensure that any lifting device used is in good condition and of suitable lift capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury to
personnel.
NOTE
Three air tanks together weigh 132 lb (60 kg).
3.
Position air tanks (20) on machine and install four
20
21,22,23
bolts (21), eight washers (22), and four nuts (23).
NOTE
Remove old antiseizing tape from male fittings and apply new tape before connections are made.
4.
Connect hose (16) and tighten nut (17).
16
15
14
5.
Connect hose (15) and tighten nut (14).
6.
Connect hose (19) and tighten nut (18).
18
19
17