TM 5-3800-205-23-1
AIR TANKS REPLACEMENT - CONTINUED
0094 00
INSTALLATION - CONTINUED
7.
Connect hose (13) and tighten nut (12).
8.
Connect hose (11) and tighten nut (10).
11
13
10
12
9.
Connect hose (8) and tighten nut (7).
10.
Connect tube (9) and tighten two nuts (6).
11.
Install hose (5) and tighten two nuts (4). Secure hose with two new tiedown straps.
12.
Install tube (2) and tighten two nuts (1) on air tanks (3).
2
6
1
1
7
3
6
8
4
3
9
3
5
4
13.
Place battery disconnect switch in ON position (TM 5-3800-205-10-1 or TM 5-3800-205-10-2).
WARNING
If machine is parked indoors, DO NOT run engine unless exhaust fumes are vented to the outside. Failure to
follow this warning may cause injury or death due to carbon monoxide poisoning.
14.
Start engine and fully charge air system (TM 5-3800-205-10-1 or TM 5-3800-205-10-2).
15.
With assistance, check for air leaks.
END OF WORK PACKAGE
0094 00-6