TM 5-3800-205-23-1
TRANSMISSION OIL AND SCAVENGER PUMP REPLACEMENT - CONTINUED
0149 00
INSTALLATION
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during proce-
dure. Ensure that any lifting device used is in good condition and of suitable lift capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury to
personnel.
NOTE
Pump weighs 50 lb (23 kg).
1.
Attach a nylon sling and suitable hoist to pump (3) and position pump at torque converter.
NOTE
3
Lightly coat new O-rings with clean oil
prior to making hose and tube connections
to pump.
2.
Install pump (3) to torque converter with four bolts
(11). Tighten bolts to 36 lb-ft (49 Nm)
3.
Connect hose (10) to pump (3) and tighten retaining
nut (11).
9
10
4.
Connect hose (7) to pump (3) and tighten retaining nut
8
7
(8).
3
0149 00-5