TM 5-3800-205-23-1
ELEVATOR/WATER PUMP CONTROL VALVE REPLACEMENT - CONTINUED
0161 00
REMOVAL
1.
Relieve hydraulic system pressure by moving control
levers through all positions (TM 5-3800-205-10-1 or
1,2
3
TM 5-3800-205-10-2).
2.
Remove nut (1) and clamp (2) from elevator control
valve (3).
3.
Remove screw (3) and clamp (5) from bracket (7).
4.
Remove electrical connection (6) from clamp (5) and
disconnect. Lay cables aside.
4,5
6
7
5.
Loosen retaining nut (10) and remove hose (11) and
O-ring (12) from elevator control valve (3). Discard
8
9
O-ring.
6.
Remove cotter pin (8), pin (9), and yoke rod end (13)
from elevator control valve (3). Discard cotter pin.
13
11,12 10
3
0161 00-2