TM 5-3800-205-23-1
ELEVATOR/WATER PUMP CONTROL VALVE REPLACEMENT - CONTINUED
0161 00
INSTALLATION - CONTINUED
11.
Install yoke rod end (13) on elevator control valve (3)
with install pin (9) and new cotter pin (8).
8
9
12.
Position hose (11) and new O-ring (12) on elevator
control valve (3) and tighten retaining nut (10).
13
11,12 10
3
13.
Connect electrical connection (6) and install in clamp
(5).
1,2
3
14.
Install clamp (5) on bracket (7) with screw (4).
15.
Install clamp (2) on elevator control valve (3) with nut
(1).
4,5
6
7
16.
WARNING
If machine is parked indoors, DO NOT run engine unless exhaust fumes are vented to the outside. Failure to
follow this warning may cause injury or death due to carbon monoxide poisoning.
17.
Operate hydraulic system and check for leaks.
END OF WORK PACKAGE
0161 00-9