TM 5-3805-248-23-1
LIGHTING SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0012 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
Cutting Edge Worklight Is
Inoperative - Continued.
terminal on cutting edge worklight
relay that green wire was removed
from (relay side) and multimeter
negative lead to chassis ground.
394-1582
e. Place battery disconnect switch in
ON position (TM 5-3805-248-10).
f. Place light switch in SER DRIVE
1. If battery voltage is indicated, repair
position.
open circuit between cutting edge
worklight and cutting edge worklight
2. If battery voltage is not indicated, go to
Test 4.
4.
Check for voltage to cutting edge
worklight relay.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
0012 00-8