TM 5-3805-248-23-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0020 00
Table 1. Unit Preventive Maintenance Checks and Services (PMCS) for 621B Scraper - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
19
1000 Hours
Air Dryer
Replace desiccant (WP 0301 00).
or Semi-
Annually
20
1000 Hours
ROPS
Re-torque bolts to 545 lb-ft (739 Nm)
or Semi-
Annually
21
1000 Hours
Transmis-
or Semi-
sion
Annually
c. Clean transmission breather (WP
22
1000 Hours
Differential
Clean breather or replace as necessary
or Semi-
Annually
23
2000 Hours
Valve Lash
Adjust valve lash (WP 0265 00).
or Annually
Adjustment
24
2000 Hours
Cooling Sys-
or Annually
tem
0020 00-5