TM 5-3805-248-23-1
THERMOSTAT AND HOUSING REPLACEMENT - CONTINUED
0046 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear protective goggles or face shield.
1.
Remove all gasket material from mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry all parts with compressed air.
4.
Inspect all parts for damage and replace as necessary.
TESTING
1.
Test thermostat (7) by suspending in container of
water heated to 197F (92C).
2.
Completely immerse thermostat (7) in water, then
shake.
3.
Soak thermostat (7) for ten minutes. Keep water at a
minimum of 197F (92C).
4.
Remove thermostat (7).
5.
Measure distance that regulator is open. If less than
0.375 in. (9.53 mm), replace thermostat (7).
7
394-054
0046 00-3