TM 5-3805-248-23-1
LOW AIR PRESSURE WARNING LAMP SWITCH REPLACEMENT - CONTINUED
0094 00
REMOVAL
NOTE
Tag all wire connectors, cables and wiring harnesses before disconnecting to ensure correct installation.
1.
Remove two screws (1) and washers (2) from switch (3).
2.
Disconnect two wire connectors (4).
3.
Remove switch (3).
1,2
4
3
394-104
INSTALLATION
1.
Wrap threads of switch (3) with anti-seizing tape and install.
2.
Connect two wire connectors (4).
3.
Install two washers (2) and screws (1).
4.
5.
6.
Verify correct operation of warning alarm (TM 5-3805-248-10).
END OF WORK PACKAGE
0094 00-2