ADJUSTMENT
1.
Turn bolt (4) until pedal (3) is parallel with floor without moving plunger (11).
2.
Turn bolt (4) until distance (A) is 0.16 in. (4.0 mm.). Repeat steps 1 and 2 until proper dimension is obtained.
3.
Tighten nut (5)
4.
Adjust bolt (25) to 0.75 in. as shown.
4
3
11
A
5
0.75 IN.
0.16 IN.
25
5.
6.
7.
Operate machine and verify proper operation (TM 5-3805-248-10).