TM 5-3805-248-23-1
HEIGHT CONTROL VALVE REPLACEMENT - CONTINUED
0215 00
REMOVAL - CONTINUED
2.
Disconnect hose assembly (2) from top of height control valve (10).
3.
Disconnect hose assembly (6) from bottom of height control valve (10).
4.
Disconnect tube assembly (5) from top of height control valve (10).
5.
If damaged, remove elbow (1), strainer (14) and preformed packing (15). Discard preformed packing.
6.
If damaged, remove reducer (16) and preformed packing (11). Discard preformed packing.
7.
If damaged, remove adapter (12) and preformed packing (13). Discard preformed packing.
8.
If damaged, remove elbow (7), adapter (8) and preformed packing (9). Discard preformed packing.
9.
If damaged, remove elbow (3) and preformed packing (4). Discard preformed packing.
2
1
3,4
5
394-380
14,15,16
10
11,12,13
6
7,8,9
10.
Remove screw (20), washer (21) and slide (22) from valve actuator rod (23).
11.
Remove two nuts (17) and sleeves (18) from height control valve (10).
12.
Remove height control valve (10) and actuator (23) from seat.
13.
Remove two valve actuator assemblies (19) from height control valve (10).
10
20,21
17,18,19
394-387
394-387
23
22
0215 00-2