TM 5-3805-248-23-1
AIR HORN SOLENOID AND HOSE ASSEMBLY REPLACEMENT - CONTINUED
0219 00
INSTALLATION
NOTE
Apply anti-seizing tape half way up the threads of all hose and fitting connections prior to installation to
ensure correct sealing.
2
1
3
4
5
394-398
1.
If removed, install nipple (5).
2.
Install solenoid valve (4) on nipple (5).
3.
Install elbow (2) on solenoid valve (4).
4.
Connect two wire connectors (3) to solenoid valve (4).
5.
Connect hose assembly (1) to elbow (2).
6.
7.
Operate air horn to verify correct operation (TM 5-3805-248-10).
8.
9.
Check for air leaks around fittings and lines (TM 5-3805-248-10).
END OF WORK PACKAGE
0219 00-2