TM 5-3805-248-23-2
FUEL TRANSFER PUMP MAINTENANCE - CONTINUED
0275 00
REMOVAL
NOTE
Tag lines prior to removal to ensure correct installation.
Use container to capture draining fuel. Dispose of fuel IAW local policy and ordinances. Ensure all
spills are cleaned up.
1.
Disconnect two lines (1) from fuel transfer pump (4).
2.
Remove two bolts (2), securing fuel transfer pump (4) to fuel injection pump housing.
3.
Remove fuel transfer pump (4).
4.
Remove gasket (3) from fuel transfer pump (4). Discard gasket.
1
4
4
394-482
3
2
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may cause
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Remove all gasket material from mounting surface.
2.
Clean all parts with solvent cleaning compound.
3.
Visually inspect parts for damage. Replace damaged parts as necessary.
4.
Dry parts with compressed air.
0275 00-2