TM 5-3805-248-23-2
HITCH LINKS MAINTENANCE - CONTINUED
0313 00
REMOVAL - CONTINUED
17.
If damaged, remove four lubrication fittings (24) from link (3).
NOTE
23
Remove bearings only if inspection indi-
cates replacement is necessary.
18.
If necessary, use puller to remove and discard four
24
3
394-989
CLEANING
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may cause
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Remove all seal and preformed packing material from mounting surfaces.
2.
Clean all parts with solvent cleaning compound.
3.
Dry all parts with compressed air.
0313 00-4