TM 5-3805-248-23-2
HYDRAULIC TANK FILTER BY-PASS VALVE REPAIR - CONTINUED
0326 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may cause
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Remove gasket material from all mounting surfaces.
2.
Clean all parts with solvent cleaning compound.
3.
Dry all parts with compressed air.
4.
Inspect all parts for damage and replace as necessary.
ASSEMBLY
1.
Install new preformed packing (11) and plug (10) on cover (1).
2.
Install ball (12) on cover (1).
3.
Install new preformed packing (13) on cover (1).
4.
Install spring (14) on cover (1).
5.
Install retainer assembly (15) and bolt (16) on cover (1).
6.
Install shaft (8) and plate (6) on housing (2).
7.
Install retainer (5), spring (4) and retainer (9) on housing (2).
8.
Compress spring (4).
9.
Install pin (7) in shaft (8).
10.
Install three screws (3) and mounting housing (2)
assembly on cover (1) assembly.
1
2
3
394-1079
11.
Install hydraulic tank oil filter cover (WP 0229 00).
12.
Check for leaks at the by-pass valve.
13.
Operate machine and verify correct operation (TM 5-3805-248-10).
END OF WORK PACKAGE
0326 00-3/-4 Blank