TM 5-3805-248-23-2
AIR-FUEL RATIO CONTROL MAINTENANCE - CONTINUED
0355 00
CHECK AND ADJUSTMENT OF FUEL RATIO CONTROL LINKAGE - CONTINUED
49
50
51
394-1726
394-1727
NOTE
When rod is turned out, there may be a small initial movement of dial indicator needles. Needles will stop
moving while rod is turned out for approximately 1-1/2 additional turns. Indicator needles will begin to
move again and will follow turning of knob until setting is reached. It is important that rod be turned slowly
so fuel rack can follow movement of governor components.
7.
Refer to Fuel Setting Procedure in WP 0354 00 for correct static fuel ratio control (lever) setting dimension, and com-
pare it to dial indicator reading. Dial indicator reading must be within + .010 in. (.25 mm) of dimension given in fuel set-
ting procedure, or an adjustment is needed.
50
52
394-1729
394-1728
0355 00-15