TM 5-3805-260-10
55
Ether Starting Aid-Changing the Cylinder
Ether is poison and flammable.
Do not smoke while changing cylinder.
Use only in well ventilated areas.
Use with care to avoid fires.
Do not store replacement ether cylinders in living areas or in operators compartment-keep out of the reach of
children.
Avoid breathing of vapors or repeated contact with skin.
Do not store cylinders at temperatures above 120°F (48.9ºC).
Do not use cylinders in environments above 200°F (93.3°C).
Do not store cylinders in direct sunlight.
Do not puncture or burn cylinders.
Discard cylinders in a safe place.
Typical Photographs
1.
Loosen the clamp 1 and unscrew the ether cylinder
2 .
2.
Remove the used gasket and install the new gasket
provided by with each new cylinder.
3.
Install the new Caterpillar Part Number 7N296 cylinder. Tighten the cylinder hand tight. Refasten the cylinder clamp
securely around the cylinder.
2-67
WARNING