TM 5-3805-260-24
GOVERNOR CONTROL LEVER AT:
PRESSURE
PRESSURE TAP
MINIMUM SETTING
MAXIMUM SETTING
ADJUSTMENT
LOCATION
Pump
(F)
260 psi (18.3 kg/cm2) (1793 kPa)
310 15 psi (21.8 1.1 kg/cm2)
NONE. Adjustment is
Filter Cover
Minimum. Check in all forward and
(213 7 103 kPa). Check in all
controlled by the
reverse speeds.
forward and reverse speeds.
modulation relief
valve.
Speed Clutch
(D) P1
73 3 psi (5.1 0.21 kg/cm2) (503
Add or remove spacers
(Primary
Pressure Control
21 kPa) with selector lever in
(21) behind modulation
Setting)
Valve
NEUTRAL.
relief valve (2). See
spacer chart.
Speed Clutch
(D) P1
260 psi (18.3 kg/cm2) (1 793 kPa)
310 15 psi (21.8 ± 1.1 kg/cm2)
NONE. Adjustment is
Pressure Control
Minimum. Check in all forward and
(2137 ± 103 kPa). Check in all
controlled by the
Valve.
reverse speeds.
forward and reverse speeds.
modulation relief
valve.
Direction
(E) P2
50 8 psi (3.5 0.621 kg/cm2) (345
50 8 psi (3.5 0.6 kg/cm2) (345
NONE.
Clutch
Pressure Control
55 kPa) less than the pressure of ±
55 kPa) less than the pressure of
Valve
the speed clutch. Check in all
the speed clutch. Check in all
forward and reverse speeds.
forward and reverse speeds.
Transmission
(C)
1 psi (0.1 kg/cm2) (7 kPa)
10 3 psi (0.7 0.2 kg/cm2) (69
NONE.
Lubrication
On transfer
Minimum. Check in all forward and
21 kPa). Check in all forward and
Oil
gear case
reverse speeds.
reverse speeds.
Outlet from
(B)
2 psi (0.1 kg/cm2) (14 kPa)
40 ± 5 psi (2.8 0.4 kg/cm2) (276
NONE.
the Torque
On converter
Minimum with selector lever in
35 kPa) with selector lever in
Controlled by
Converter
housing near
THIRD SPEED forward, brakes
THIRD SPEED forward, brakes
orifice.
outlet line to
activated and converter stalled.
activated and converter stalled.
oil cooler
Inlet to the
(A) P3
1 125 psi (8.1 kg/cm2) (793 kPa)
NONE.
Torque
Pressure Control
Maximum.
Converter:
Valve
BENCH TEST
for correct
operation
2-100