TM 5-3805-260-24HYDRAULIC TANK6.Loosen clamp (9) to disconnect hose (10) from the intakemanifold.7.Remove the four nuts (11) and washers that hold the aircleaner panel assembly to the machine.8.Remove bolt (12), the nut and washer that hold the top of theair cleaner panel assembly.9.Remove the five bolts, the nut and washer that hold handleassembly (14) in position. Remove handle assembly (14).10.Remove the air cleaner and panel assembly (13) as a unit.11.Remove the eight bolts (15), nuts and washers that hold thefender to the tank.3-262