TM 5-3800-205-23-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0007 00
Table 5. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check for burned out bulb(s).
a. If bulb(s) is burned out,
14. Water Distributor Control Panel Water
replace bulb(s) (TM 5-3800-
Level Green/Red Panel Indicator Lights Do
205-23-3).
Not Come On.
b. If bulb(s) is okay, go to test
step 2.
a. Reconnect
connector
if
2. Check connector of control
required.
panel electrical harness at
receptacle connector on side
of cab (TM 5-3800-205-10-
2).
b. If problem still exists, go to
test step 3.
a. Reconnect connector if
3. Check electrical connection
at tank water level sender for
and problem still exists, go to
tightness and continuity (TM
step b.
5-3800-205-23-3).
b. Replace water level sender
(TM 5-3800-205-23-3).
15. Water Distributor Work Lights Inoperative.
1. Check for blown fuse.
if required.
b. If problem still exists, go to
test step 2.
2. Check work lights for damage
a. Replace burned out/damaged
or burned out lamps.
lamps (TM 5-3800-205-23-
3).
b. If problem still exists, go to
test step 3.
a. Repair or replace damaged
3. Check wiring harness and
connectors for damage,
of 24 Vdc.
b. If problem still exists, go to
test step 4.
4. Check flood enable relay for
Replace flood enable relay
damage or shorts.