TM 5-3800-205-23-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0007 00
Table 5. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
Turn signals or hazard lights will not operate if machine is in blackout mode.
a. Select STOP LIGHT or SER.
5. Directional Turn Signal or Hazard Flasher
1. Check if STOP LIGHT or
DRIVE.
Control are Not Working.
SER. DRIVE function has
been selected on lighting key
pad.
b. If problem still exists, go to
test step 2.
NOTE
A thirty (30) minute cool down time may be required before circuit breaker can be reset.
2. Check that circuit breaker is
a. If circuit breaker will not
not tripped.
reset after thirty (30)
minutes, replace circuit
b. If problem still exists, go to
test step 3.
3. Check that B.O. drive light
a. If circuit breaker does not
circuit breaker is not tripped.
reset after thirty (30)
minutes, replace circuit
b. If problem still exists, go to
test step 4.
a. Replace damaged/burned out
4. Check turn signal/hazard
flasher lights for damaged or
burned out bulbs.
b. If problem still exists, go to
test step 5.
Repair/replace damaged wires
5. Check wiring harness and
connectors for damage,
of 24 Vdc.
6. Check flasher unit for damage
Replace damaged/shorted
or shorts.
7. Check turn/flash relay for
Replace shorted/damaged relay
shorts or damage.
8. Check turn signal/hazard
flasher switch and wiring for