TM 5-3800-205-23-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0007 00
Table 5. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a. Repair or replace damaged
3. Check wiring harness and
3. Blackout Drive Light(s) Do Not Operate When
connectors for damage,
B.O. MARKER Function is Selected -
Continued.
of 24 +/- 6 Vdc.
b. If problem still exists, go to
test step 4.
4. Check light switch
for
damage and continuity.
NOTE
Lamps will not operate if machine is in blackout mode.
a. Select STOP LIGHT or SER.
4. Cutting Edge/Bowl Work Light Inoperative.
1. Check if STOP LIGHT or
DRIVE.
SER. DRIVE function has
been selected on lighting key
pad.
b. If problem still exists, go to
test step 2.
2. Check for blown fuse and/or
if required.
tripped B.O. drive light circuit
breaker.
b. If circuit breaker does not
reset after thirty (30)
minutes, replace circuit
c. If problem still exists, go to
test step 3.
3. Check work lights for damage
a. Replace burned out/damaged
or burned out lamps.
5-3800-205-23-2).
b. If problem still exists, go to
test step 4.
a. Repair or replace damaged
4. Check wiring harness and
connectors for damage,
of 24 Vdc.
b. If problem still exists, go to
test step 5.
5. Check flood enable relay for
Replace flood enable relay
damage or shorts.