TM 5-3800-205-23-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0007 00
Table 2. Charging System Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
A thirty (30) minute cool down time may be required before circuit breaker can be reset.
1. Check that circuit breaker is
Reset circuit breaker. If problem
not tripped.
still exists, go to test step 2.
2. Check for loose or broken
a. Tighten loose drive belt(s)
drive belt(s).
b. Replace broken drive belt(s)
c. If problem still exists, go to
test step 3.
3. Check for loose connections
a. Tighten
any
loose
b. If problem still exists, go to
test step 4.
to test step 5.
Replace circuit breaker if
voltage indication is more than
Voltage Test (WP 0005 00).