TM 5-3800-205-23-1
INJECTOR SYNCHRONIZATION, FUEL SETTING, AND FUEL TIMING - CONTINUED
0140 00
FUEL TIMING - CONTINUED
4.
Slide indicator (35) in magnetic base group (38) until it stops.
5.
Ensure that magnetic bottom of indicator fixture group is clean of all particles sticking to magnet.
6.
Ensure both top and shoulder of timing gage block (39) are clean.
7.
Install indicator (35) and base on timing gage block (39).
CAUTION
Be careful when attaching magnetic base group to any surface when indicator is attached to base. Magnets in
base are very powerful. To reduce possibility of damaging indicator as base "snaps" in place, push indicator
plunger to its fully retracted position and hold it. Once base attaches to a surface, let plunger out.
8.
Repeat steps 2a through 2c above.
9.
Momentarily press PRESET button. Display should now indicate 62.00 mm. Lift up on indicator tip slightly. Displayed
numbers should decrease. If this is not the case, repeat steps 2 through 6 above.
10.
Ensure top surfaces of injector tappet (40) and shoul-
41
40
der are clean and dry.
0140 00-23