TM 5-3805-248-23-1
BATTERY, STARTING AND CHARGING SYSTEM TROUBLESHOOTING
PROCEDURES - CONTINUED
0010 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
Engine Cranks Slowly.
6.
Test negative cable voltage drop from
Continued.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
b. Set multimeter to appropriate
negative terminal on starting motor
chassis ground.
MTR
S
(+)
(-)
BAT
394-1564
d. Pull accelerator pedal past detent to
1. If voltage exceeds 0.4 volts, clean and
prevent engine from starting and
tighten cable connections at batteries,
crank engine and observe meter
starting motor and chassis ground
(TM 5-3805-248-10).
points.
2. If problem still exists, go to Test 7.
7.
Test positive cable voltage drop from
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
b. Set multimeter to appropriate
0010 00-14