TM 5-3805-248-23-1
BATTERY, STARTING AND CHARGING SYSTEM TROUBLESHOOTING
PROCEDURES - CONTINUED
0010 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
Engine Cranks Slowly.
d. Pull accelerator pedal past detent to
1. If voltage exceeds 0.4 volts, clean and
Continued.
prevent engine from starting and
tighten cable connections at batteries,
crank engine and observe
starting motor and chassis ground
points.
2. If problem still exists, go to Step e.
across battery terminals as shown.
394-1566
f. Pull accelerator pedal past detent to
1. If voltage is not 20 volts or more, go to
prevent engine from starting and
Malfunction 2.
crank engine for approximately 30
2. If voltage is satisfactory, replace
seconds. Observe multimeter
reading after cranking has stopped.
0010 00-16