TM 5-3805-248-23-1
ELECTRICAL ACCESSORIES TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
d. Place battery disconnect switch in
1. If battery voltage is not indicated, repair
9.
Horn Is Inoperative -
ON position (TM 5-3805-248-10).
open circuit between backup alarm/horn
Continued.
2. If battery voltage is indicated, go to Test
6.
6.
Check for voltage to horn solenoid.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
white wire of horn solenoid (harness
side) and meter negative lead to
chassis ground.
394-1641
e. Place battery disconnect switch in
1. If battery voltage is not indicated, repair
ON position (TM 5-3805-248-10).
2. If battery voltage is indicated, go to Test
7.
7.
switch and horn solenoid.
a. Place battery disconnect switch in
OFF position (TM 5-3805-248-10).
0011 00-21