TM 5-3805-248-23-1
LOW AIR PRESSURE WARNING LAMP REPLACEMENT - CONTINUED
0061 00
REMOVAL
1.
Remove lens (1) from instrument panel (8).
2.
Remove lamp (2).
NOTE
Tag all wire connectors, cables and wiring harnesses prior to removal to ensure correct installation.
3.
Disconnect two wire connectors (7).
1
4.
Remove nut (5) and lockwasher (6). Discard lock-
washer.
2
5.
Remove base (3) and plate (4).
3
4
394-204
5,6
7
8
INSTALLATION
1.
Install plate (4) and base (3) on instrument panel (8).
2.
Install new lockwasher (6) and nut (5).
3.
Connect two wire connectors (7).
4.
Install lamp (2).
5.
Install lens (1).
6.
7.
8.
Operate machine (TM 5-3805-248-10) and verify indicator operates correctly.
END OF WORK PACKAGE