TM 5-3805-248-23-1
ETHER START SENDING UNIT REPLACEMENT - CONTINUED
0098 00
REMOVAL
1.
Remove screw (1) and lockwasher (2) from temperature switch (4).
2.
Disconnect wire connector (3).
3.
Remove sending unit (4).
4 3
2
1
INSTALLATION
1.
Wrap threads of sending unit (4) with anti-seizing tape and install.
2.
Connect wire connector (3).
3.
Install new lockwasher (2) and screw (1).
4.
5.
6.
Verify correct operation of ether starting aid (TM 5-3805-248-10).
END OF WORK PACKAGE
0098 00-2