TM 5-3805-248-23-1
HOUR METER SWITCH REPLACEMENT - CONTINUED
0097 00
REMOVAL
NOTE
Tag all wires before disconnecting to ensure correct installation.
1.
Remove two screws (1) and washers (2) from hour meter switch (3).
2.
Disconnect two wire connectors (4).
3.
Remove hour meter switch (3).
1,2
3
4
INSTALLATION
1.
Install hour meter switch (3).
2.
Install two wire connectors (4).
3.
Install two washers (2) and screws (1).
4.
5.
6.
Verify correct operation of hour meter (TM 5-3805-248-10).
END OF WORK PACKAGE
0097 00-2