TM 5-3805-248-23-1
MAIN CIRCUIT BREAKER-TO-STARTING MOTOR SOLENOID WIRE
REPLACEMENT - CONTINUED
0110 00
REMOVAL
NOTE
Tag all wire connectors, cables and wiring harnesses before disconnecting to ensure correct installation.
1.
Remove screw (4) and lockwasher (3). Discard lockwasher.
2.
Disconnect wiring harness (2) connector from side of operator compartment.
3.
Remove lockwasher (1) and discard.
NOTE
Keep wire connectors attached to retaining strap and one of two clips.
4.
Remove bolt (7) and washer (6) from retaining strap (8) and clips (5 and 12).
5.
Remove clip (5).
6.
Remove two bolts (9), washers (10) and clips (11).
7.
Disconnect wire harness (2) connector from starting motor (WP 0057 00).
NOTE
Note routing of wiring harness to ensure correct installation.
8.
Remove wiring harness (2) from machine.
12
1
2
3
4
5
6
7
11
10
9
8
394-235