TM 5-3805-248-23-1
DIFFERENTIAL BREATHER REPLACEMENT - CONTINUED
0142 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may cause
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear eye protection.
1.
Clean breather with solvent cleaning compound.
2.
Dry parts with compressed air.
3.
Inspect for damage and replace if necessary.
INSTALLATION
Install breather (1) in differential housing (2).
1
394-302
2
END OF WORK PACKAGE
0142 00-2