TM 5-3805-248-23-1
INSTRUCTION AND DATA PLATES REPLACEMENT - CONTINUED
0227 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the area.
To prevent injury, user must wear protective goggles or face shield.
1.
Remove all adhesive from mounting surfaces.
2.
Clean all parts with solvent.
3.
Dry all parts with compressed air.
INSTALLATION
NOTE
When installing lubrication label, partially remove backing along one edge and attach to machine. While
moving across lubrication label, peel off backing and attach to machine. Continue until lubrication label is
completely attached.
1.
Install new lubrication label (3).
2.
Install transportation data plate (2) and four new drive screws (1).
END OF WORK PACKAGE
0227 00-3/(-4 blank)