TM 5-3805-248-23-2
CONTROL LEVER LINKAGE REPLACEMENT - CONTINUED
0325 00
REMOVAL - CONTINUED
3.
Remove cotter pin (8) and pin (6). Discard cotter pin.
6
4.
Separate clevis of rod (7) from apron control valve
spool (9).
7
8
9
394-1055
NOTE
Steps 5 through 12 are the procedure for removal of ejector lever linkage from hydraulic control valve spool
to the remote valve spool to the remote lever bracket. The maintenance procedure for the apron and bowl
lever linkage segments is identical.
5.
Remove cotter pin (14) and pin (13). Discard cotter
13
14
12
pin.
11
6.
Separate clevis (16) assembly from hydraulic control
valve spool (15).
15
7.
Remove cotter pin (12) and pin (11). Discard cotter
10
pin.
8.
Remove clevis (16) assembly from lever (10).
16
394-1064
9.
Loosen nut (19) on clevis (16).
17
18
10.
Remove clevis (17), retainer (18) and nut (19) from
19
clevis (16).
16
394-1065
0325 00-2