TM 5-3805-248-23-2
SCRAPER CONTROL VALVE REPLACEMENT - CONTINUED
0323 00
TESTING AND ADJUSTMENT - CONTINUED
Ejector Kickout Valve - Continued
5.
Start engine and run at high idle (TM 5-3805-248-10).
6.
Move ejector gate return lever. Observe gage (8) while
gate is moving. When pressure is 1,600200 psi
16
(11,0321,379 kPa), kickout valve should open and
move control lever to hold position. If pressure setting
15
is incorrect, continue with following steps.
394-1062
7.
Remove plug (15) from ejector kickout valve (16).
16
17
8.
Adjust screw (17). Insert 0.125 in. (3.175 mm) hex
wrench into housing (16) through spring into adjusting
15
screw. Turn screw clockwise to increase and counter-
clockwise to decrease pressure. One turn of screw
changes pressure setting 170 psi (1,172 kPa).
9.
Install plug (15) in housing (16).
10.
Start engine. Check gage (8). If reading is correct,
remove gage and install plug (5). If reading is not cor-
394-1063
rect, repeat steps 7 through 10.
11.
Fill hydraulic oil tank (TM 5-3805-248-10).
12.
END OF WORK PACKAGE
0323 00-5/-6 Blank