TM 5-3805-248-23-2
CONTROL LEVER LINKAGE REPLACEMENT - CONTINUED
0325 00
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may cause
injury or death. Make sure air stream is directed away from user and other personnel in the area. To pre-
vent injury, user must wear protective goggles or face shield.
1.
Remove gasket material from all mounting surfaces.
2.
Clean all parts with solvent cleaning compound.
3.
Dry all parts with compressed air.
4.
Inspect all parts for damage and replace as necessary.
INSTALLATION
1.
Install two bearings (62) in lever (34).
58
59
2.
Install bearing (60) in connecting link (58).
57
60
3.
Install washer (59), connecting link (58), washer (57)
61
and shaft (63) in lever (34).
62
4.
Install pin (61) in connecting link (58).
62
63
34
394-1076
NOTE
Do not tighten nuts until adjustment is made to rod lengths.
5.
Install two nuts (55) and rod ends (54) and (56) on rod
54
(53).
55
53
55
56
394-1075
0325 00-8