TM 5-3805-248-23-2
FUEL INJECTION PUMP REPAIR - CONTINUED
0353 00
ASSEMBLY/ADJUSTMENT - CONTINUED
51.
Measure depth micrometer chamber 2 timing dimension. Read measurement and record chamber 2 timing dimension.
52.
Remove depth micrometer and gage.
53.
Rotate timing plate counterclockwise to mark 166.75 degrees.
54.
Install depth micrometer and gage in chamber 6.
55.
Measure depth micrometer chamber 6 timing dimension. Read measurement and record chamber 6 timing dimension.
56.
Remove depth micrometer and gage.
57.
Rotate timing plate counterclockwise to mark 106.75 degrees.
58.
Install depth micrometer and gage in chamber 3.
59.
Measure depth micrometer chamber 3 timing dimension. Read measurement and record chamber 3 timing dimension.
60.
Remove depth micrometer and gage.
61.
Rotate timing plate counterclockwise to mark 46.75 degrees.
62.
Install depth micrometer and gage in chamber 5.
63.
Measure depth micrometer chamber 5 timing dimension. Read measurement and record chamber 5 timing dimension.
NOTE
Steps 63 through 67 are the procedure to determine the thickness of spacer required in each pump housing
chamber. Complete these steps for each chamber before proceeding to step 68.
64.
Compare recorded timing dimension for each chamber
to required timing dimension range of 4.342-4.346 in.
(110.286-11.038 mm). If within range, do not replace
spacer (16). If greater than 4.346 in. (110.388 mm),
refer to Table 1, Example A. If less than 4.342 in.
GAGE
(110.286 mm), refer to Table 1, Example B.
65.
If spacer (16) must be replaced, complete steps 65 and
66. If spacer does not need to be replaced, proceed to
4-5 IN. (101.6-127 mm)
step 67 after all six chambers have been serviced.
ROD
TIMING DIMENSION
INJECTION
PUMP CHAMBER
16
394-1209
0353 00-12