TM 5-3805-248-23-2
STARTING MOTOR SOLENOID REPLACEMENT - CONTINUED
0360 00
CLEANING AND INSPECTION
1.
Remove all gasket material from mounting surfaces.
2.
Wipe all parts with clean rag.
3.
Inspect all parts for damage and replace as necessary.
INSTALLATION
1.
Position solenoid (4) and slide solenoid onto plunger,
4
3
aligning mounting holes on starting motor (6).
5
2.
Install four screws (5).
2
3.
1
(8). Torque two nuts to 22 lb-ft (30 Nm).
4.
Connect wire connector (3) to solenoid (4).
PLUNGER
8
9
5.
Install lockwasher (2) and nut (1).
8
7
6
394-069
6.
7.
Connect battery cables (WP 0104 00).
END OF WORK PACKAGE
0360 00-2